Name | Cooley Graft Suction Tube |
Lead Time | 0-3 days |
Competitor | ;GF821R;CH8055;310103;310-103;0986-15; |
Specialty | General Instruments-Suction Tubes, Needles & Probes – Suction Tubes |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | BUF SURGICAL |
Sterility | Non-Sterile |
Usage | Reusable |
Cooley Graft Suction Tube
Cooley Graft Suction Tube
8.0 mm wide round perforated tip, 7″ (17.8 cm) working length, 12″ (30.5 cm) overall length
Cooley Graft Suction Tube is a popular instrument used in various surgical operations to eliminate and clear bodily fluids that may obstruct the view of the surgical site. For this reason, the distal end of the tube contains a piece that is attached to a suction machine in order to provide the suction power for the instrument to perform. The other end contains a long tube that has an 8.0 mm wide tip, which allows it to extract greater amount of fluid away from the area.
SKU:
SW-01-860
Category: Suction Tubes, Needles & Probes
Description
Reviews (0)
Be the first to review “Cooley Graft Suction Tube” Cancel reply
Shipping & Delivery
Related products
Suction Tube
Suction Tube
w/ removable tip
Yankauer Suction Tube comes with a tip that can be removeved to allow access to tighter spaces. If these tips get lost, however, they can be purchased separately to be used only for the Yankauer suction tube. This device is also long in length and can range from 10 ¼" to 18" depending on the operation. The handle of this device contains an end that can be connected to a suction source in order to provide the suction power needed to remove fluids or debris away from the surgical site.
Frazier Suction Tube – Semi-Rigid W/ Slot
Frazier Suction Tube - Semi-Rigid W/ Slot
angled, semi-rigid w/ slot, 5-1/2" (14.0 cm) working length
Frazier Suction Tube is semi-rigid with a slot on the handle. The tube is angled and is primarily utilized during general surgeries to remove any fluids or blood that may occupy the surgical site obstructing the surgeon's view. In this case, the thin diameter of the tube, in addition to the 5 ½" length, is able to enter small areas that require matter to be eliminated.
Double-Ended Probe – Silver
Double-Ended Probe - Silver
sterling silver
Double-Ended Probe is made from sterling silver material to be better fitted for general purposes due to its hardness. Additionally, the blunt points on either end help to examine body cavities or tissues without trauma. Depending on the type or location of the examination, this probe is offered in several lengths.
Adson Suction Tube
Adson Suction Tube
w/ finger cut-off, curved
Adson Suction Tube contains a finger cut-off valve to place rest the finger on and a grip handle for a better hold. This instrument is available in several different French measurements on a 5" or 8" working length. The intended purpose of this suction tube with a slightly curved tip is to remove any excess liquids or fluids that are present on the surgical site. In this way, the surgeon may have a clear view of the area being operated.
Needle Extension
Needle Extension
Needle Extension is offered in a variety of sizes to accommodate a range of cases and surgeon preference. This extension is able to spread to the length of a surgical needle and is equipped with a luer lock on one end, which provides easy attachment and removal. Additionally, this item is polished to a dull, satin finish to reduce glare under operating room lights.
Tongue Tie – Plain Point
Tongue Tie - Plain Point
stainless steel, plain point
Grooved Director and Tongue Tie contains a plain point at one end and a butterfly-shaped director on the other end. This stainless steel instrument is typically used during a frenotomy to lift the tongue back and expose the frenulum. The frenulum would rest on the grooved part of the director and then be cut with iris scissors. Depending on the patient, this device is offered in various lengths.
Mayo Vein Stripper
Mayo Vein Stripper
15-3/8" (39.0 cm)
Mayo Vein Stripper is 15 3/8" long instrument with a short grip handle and a long rod with a circular jaw. This vein stripper is typically used in procedures that require the removal of varicose veins because the use of this instrument is quicker and there are fewer infections that appear on the patient. Multiple inner diameters of the ring are available according to the type of vein that needs to be stripped.
Yankauer Suction Tube – Pediatric
Suction Tube
small pattern, narrow handle (pediatric), w/ removable tip, 8-1/4" (21.0 cm) overall length
Yankauer Suction Tube is designed to be used during general procedures involving pediatrics due to the narrow handle and smaller pattern. The reason of using this tube is to clean the surgical site, thereby also removing debris or fluids and reducing the chance for infection. The end of the tube contains a removable bulb-shaped tip, and the overall length is 8 ¼."
Reviews
There are no reviews yet.