Name | Brackman Suction Tube |
Lead Time | 0-3 days |
Competitor | ;MA497R;099505;09-9505;0995-05;N06067A;N0606-7A;099507;09-9507;90-8022;N0605 7A;908022;0995-07;0995-05_0995-07; |
Specialty | General Instruments-Suction Tubes, Needles & Probes – Suction Tubes |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | BUF SURGICAL |
Sterility | Non-Sterile |
Usage | Reusable |
Suction Tube
Suction Tube
offset suction tip holes, 3″ (7.5 cm) working length
Brackman Suction Tube contains a thumb plate on the handle to rest the finger on and also to control the bypass hole. The tube itself is either 5 or 7 French and has offset suction tip holes. These fine suction tips are designed to be used in surgeries, such as myringoplasty, for areas that are narrow or more delicate in order to avoid excess suction.
SKU:
SW-01-875
Category: Suction Tubes, Needles & Probes
Description
Reviews (0)
Be the first to review “Suction Tube” Cancel reply
Shipping & Delivery
Related products
Yankauer Suction Tube – Pediatric
Suction Tube
small pattern, narrow handle (pediatric), w/ removable tip, 8-1/4" (21.0 cm) overall length
Yankauer Suction Tube is designed to be used during general procedures involving pediatrics due to the narrow handle and smaller pattern. The reason of using this tube is to clean the surgical site, thereby also removing debris or fluids and reducing the chance for infection. The end of the tube contains a removable bulb-shaped tip, and the overall length is 8 ¼."
Suction Tube
Suction Tube
w/ removable tip
Yankauer Suction Tube comes with a tip that can be removeved to allow access to tighter spaces. If these tips get lost, however, they can be purchased separately to be used only for the Yankauer suction tube. This device is also long in length and can range from 10 ¼" to 18" depending on the operation. The handle of this device contains an end that can be connected to a suction source in order to provide the suction power needed to remove fluids or debris away from the surgical site.
Frazier Suction Tube
Frazier Suction Tube
angled, w/ finger cut-off, 4" (10.2 cm) working length
Frazier Suction Tube has an angled tube and is available in a variety of different sizes and widths depending on the operation. This tube has a finger cut-off on a 4" working length and performs similar to a pump with a suction force. The purpose of this suction force is to be used in general operations in which materials or fluid, typically blood, need to be removed to provide a cleaner working area.
Vein Stripper
Vein Stripper
complete set in stainless steel sterilizing case, includes: traction cable, handle, plastic probe tip, metal probe tip, olive adaptors (6.0 mm, 9.0 mm & 12.0 mm)
Nabatoff Vein Stripper is a complete set loaded in a stainless steel sterilizing case that includes several tools such as traction cable, handle, probe tips, and olive adaptors. This instrument is typically used during procedures that involve the removal of varicose veins. Once an incision is made around the area, the wire is inserted into the vein and tied so that the vein can be pulled out.
Cooley Graft Suction Tube
Cooley Graft Suction Tube
8.0 mm wide round perforated tip, 7" (17.8 cm) working length, 12" (30.5 cm) overall length
Cooley Graft Suction Tube is a popular instrument used in various surgical operations to eliminate and clear bodily fluids that may obstruct the view of the surgical site. For this reason, the distal end of the tube contains a piece that is attached to a suction machine in order to provide the suction power for the instrument to perform. The other end contains a long tube that has an 8.0 mm wide tip, which allows it to extract greater amount of fluid away from the area.
Frazier Suction Tube – Semi-Rigid W/ Slot
Frazier Suction Tube - Semi-Rigid W/ Slot
angled, semi-rigid w/ slot, 5-1/2" (14.0 cm) working length
Frazier Suction Tube is semi-rigid with a slot on the handle. The tube is angled and is primarily utilized during general surgeries to remove any fluids or blood that may occupy the surgical site obstructing the surgeon's view. In this case, the thin diameter of the tube, in addition to the 5 ½" length, is able to enter small areas that require matter to be eliminated.
Frazier Suction Tube Stylet
Frazier Suction Tube Stylet
Frazier Suction Tube Stylet is a thin wire device that serves the purpose of clearing any contents that remain inside the Frazier Suction Tube. All of the sizes offered of this stylet are specifically designed to enter each of the various sizes and thickness of the Angled Frazier Suction Tube with finger cut-off and 4" working length.
Tongue Tie – Plain Point
Tongue Tie - Plain Point
stainless steel, plain point
Grooved Director and Tongue Tie contains a plain point at one end and a butterfly-shaped director on the other end. This stainless steel instrument is typically used during a frenotomy to lift the tongue back and expose the frenulum. The frenulum would rest on the grooved part of the director and then be cut with iris scissors. Depending on the patient, this device is offered in various lengths.
Reviews